McDATA Intrepid 6000 Series Directors
Timeout Values
P
AGE 238 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
For the QLogic SANbox2-64, the following displays:
4. From the Switch PropertiesSANbox Manager dialog box Administrative State list, select
offline. Click OK.
5. Re-enter the Switch PropertiesSANbox Manager dialog box (see step 2). Do the
following:
a. In the R_A_TOV box, change the setting to 10000.
b. In the E_D_TOV box, change the setting to 2000.
c. Click OK.
6. Re-enter the Switch PropertiesSANbox Manager dialog box (see step 2). In the
Administrative State list, select Online. Click OK.
Vedere la pagina 249